CS106/BL106 Combined Door Entry and Coded Access
6
General Description
The C106 Coded Access Controller is a high quality, versatile security product,
controlling access to a door by means of a keypad and an electric lock release
mechanism.
Basic Operation
The C106 Keypad may be programmed with up to 10 unique access codes. If
a valid code is entered on the keypad, the lock release will operate for a preset
duration.
The keypad has one green and one red LED to indicate the system status to the
user; the green LED indicates that the lock release is operating, whilst the red
LED indicates an invalid entry.
Other Features:
Multiple codes
The C106 has 10 access codes available each of which can be 1 to 8 digits long.
The extra codes are provided for a variety of possible uses:-
Multi-user applications, e.g. for a small office block.
Time-restricted access (described below).
Time-Restricted Access (Staff/Executive Operation)
Any of the 10 access codes may be programmed to operate during a restricted