CS106/BL106 Combined Door Entry and Coded Access
31
button is pressed.
Lock release does not operate
when Exit Button is pressed.
Test by applying a short-circuit directly
to the ‘EXIT’ terminals; Check
connections to Exit button.
Lock operates from the test
button but does not operate
when the code is entered.
Check C106 Keypad is correctly
programmed; Restore to Factory
Settings (page 24, 32);
Time Clock in wrong state; reprogram
action code, manually switch the time
clock.
Lock release is permanently
active
‘EXIT’ terminals are short-circuited;
temporarily remove connections to
‘EXIT’ and re-test unit. Check any exit
button connected to the EXIT terminals
is ‘push to make’ and not the opposite
Can’t change any of the
settings. Green LED is on
‘EXIT’ terminals are short-circuited;
temporarily remove connections to
‘EXIT’ and re-test unit. Check any exit
button connected to the EXIT terminals
is ‘push to make’ and not the opposite